RV[N] - Recorded Variables
Purpose:
Maps recorded variables to the recorder through the RC command. By setting RV[N]=X,
bit N-1 of RC is assigned the X variable in the variable static table. The default mapping
(power on) of RV[1] - RV[16] behaves similarly to previous projects. The full list of
variables available to the recorder is stored in the serial flash memory of the
SimplIQ
drive and can be uploaded using the LS command.
Attributes: Type: Parameter, Integer, Bit-field
Source: Program, RS-232, CANopen
Restrictions: None
Default values: RV[1]=1, RV[2]=2 . . . RV[16]=16
(RS), Volatile
Range: According to static table variable index.
Index range: [1…16]
Unit modes: All
Activation: Immediate
See also:
RC, BH, RR
Reference chapters in the
SimplIQ Software Manual:
Chapter 8, ”The Recorder;” Appendix A, “The
SimplIQ Flash Memory Organization”