Elmomc SimplIQ Analog Servo Amplifiers-Ocarina Installati Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Elmomc SimplIQ Analog Servo Amplifiers-Ocarina Installati. ElmoMC SimplIQ Analog Servo Amplifiers-Ocarina Installation User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Installation Guide

Ocarina/Castanet Analog Servo Drives Installation Guide February 2009 - Ver. 1.4 www.elmomc.com

Strany 2 - OCA- X/YYY

Ocarina/Castanet Installation Guide MAN-OCSIG (Ver. 1.4) Chapter 3: Installation 3.1 Before You Begin 3.1.1 Site Requirements You can guarantee th

Strany 3 - Contents

Ocarina/Castanet Installation Guide Installation MAN-OCSIG (Ver. 1.4) 3-2 3. Verify that the Ocarina or Castanet type is the one that you ordered,

Strany 4

Ocarina/Castanet Installation Guide Installation MAN-OCSIG (Ver. 1.4) 3-3 3.4 Mounting 3.4.1 Ocarina The Ocarina was designed for mounting on a pr

Strany 5

3.5 Integrating the Ocarina and Castanet on a PCB The Ocarina and Castanet are designed to be mounted on a PCB, either by soldering its pins directly

Strany 6 - 1.2 Cautions

Ocarina/Castanet Installation Guide Installation MAN-OCSIG (Ver. 1.4) 3-5 3. Main Power Supply and Motor Traces: The power traces must be kept as f

Strany 7 - 1.5 Warranty Information

3.6.2 Connector J1 Pin # Short Form Function Description 1 EN+ Enable + Positive voltage input of the “Amplifier Enable” function. To enable oper

Strany 8 - Chapter 2: Introduction

Pin # Short Form Function Description 14 ECLP External current limit peak External voltage scales down the rated value. Voltage range: 0 V to 3.75 V

Strany 9 - 2.4 How to Use this Guide

Ocarina/Castanet Installation Guide Installation MAN-OCSIG (Ver. 1.4) 3-8 3.7 Ocarina/Castanet Connection Diagram Figure 3-3: Ocarina/Castanet Co

Strany 10 - Chapter 3: Installation

Ocarina/Castanet Installation Guide Installation MAN-OCSIG (Ver. 1.4) 3-9 3.8 Main Power and Motor Power Pin Function Cable Pin Positions VP+ Po

Strany 11 - 3.3 Dimensions

3.11 DC Power Supply The DC power supply can be at any voltage in the range defined in the technical specifications (the Appendix of this guide). Th

Strany 12 - 3.4 Mounting

Notice This guide is delivered subject to the following conditions and restrictions:  This guide contains proprietary information belonging to

Strany 13 - 3.5.2 Grounds and Returns

Ocarina/Castanet Installation Guide Installation MAN-OCSIG (Ver. 1.4) 3-11 Figure 3-4: Detailed Ocarina/Castanet Internal Block Diagram

Strany 14 - 3.6 Pin Functions

3.12 Heat Dissipation 3.12.1 Ocarina The best way to dissipate heat from the Ocarina is to mount it so that its heatsink faces up. For best results

Strany 15 - 3.6.2 Connector J1

Whistle 100 Series Power Dissipation0.01.02.03.04.05.06.000.511.522.533.544.55Peak Current (A)Power Dissipation (W)85VDC70VDC50VDC 3.12.1.3 How to Us

Strany 16 - MAN-OCSIG (Ver. 1.4)

Chapter 4: Servo Control Operation 4.1 Current Command Input The Ocarina and Castanet have a single differential input. The input operating voltage

Strany 17

Ocarina/Castanet Installation Guide Servo Control Operation 4-2 MAN-OCSIG (Ver. 1.4) 4.2.2 External Resistor Connect an external resistor betwee

Strany 18

Ocarina/Castanet Installation Guide Servo Control Operation 4-3 MAN-OCSIG (Ver. 1.4) 4.2.5 External Resistor Connect an external resistor between t

Strany 19 - 3.11 DC Power Supply

Ocarina/Castanet Installation Guide Servo Control Operation Notes:  Without latch mode: The status indications are reset when the fault disappea

Strany 20

Appendix: Specifications A.1 General Specifications A.1.1 Ocarina Feature Units 1/60 2.5/60 5/60 10/60 15/60 1/100 2.5/100 5/100 10/100 15/100 Min

Strany 21 - 3.12 Heat Dissipation

A.1.2 Castanet Feature Units 3/60 2.5/100 Minimum supply voltage VDC 11 20 Nominal supply voltage VDC 50 85 Maximum supply voltage VDC 59 95

Strany 22 - Ocarina -100

A.2 Standards Compliance A.2.1 Quality Assurance Specification Details ISO 9001:2000 Quality Management A.2.2 Design Specification Details MIL-HDB

Strany 23 - 4.1 Current Command Input

Contents Chapter 1: Safety Information... 1-1 1.1 Warning

Strany 24 - 4.2.4 External Voltage

A.2.4 EMC Specification Details In compliance with EN55011 Class A with EN61000-6-2: Immunity for industrial environment, according to: IEC61000-4-2

Strany 25 - 4.3 Status Indications

4.2.2 External Resistor...4-2 4.2.3 External Current Li

Strany 26

Ocarina/Castanet Installation Guide MAN-OCSIG (Ver. 1.4) 1-1 Chapter 1: Safety Information In order to achieve the optimum, safe operation of the Oc

Strany 27 - Appendix: Specifications

1.1 Warnings To avoid electric arcing and hazards to personnel and electrical contacts, never connect/disconnect the servo drive while the power so

Strany 28 - A.1.2 Castanet

1.3 Directives and Standards The Ocarina and Castanet conform to the following industry safety standards: Safety Standard Item In compliance with U

Strany 29 - A.2 Standards Compliance

Ocarina/Castanet Installation Guide MAN-OCSIG (Ver. 1.4) 2-1 Chapter 2: Introduction This Installation Guide is intended for design engineers who ar

Strany 30 - A.2.7 Packing

Ocarina/Castanet Installation Guide Introduction MAN-OCSIG (Ver. 1.4) 2-2 2.3 Fault Protection Built-in protection against possible fault condition

Komentáře k této Příručce

Žádné komentáře