Elmomc CANopen DS 301 Implementation Guide Uživatelský manuál Strana 61

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 118
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 60
Object description:
Index 1012h
Name COB-ID time stamp message
Object code VAR
Data type UNSIGNED32
Category Optional
Entry description:
Access Read/Write
PDO mapping No
Value range UNSIGNED32
Default value 100h
According to CiA DSP 301, the 0x1012 object has read/write access, although it
only has read access with
SimplIQ digital servo drives.
Object 0x1013: Hi
gh-resolution time stamp
This object contains a time stamp with a 1-microsecond resolution.
Object description:
Index 1013h
Name High resolution time stamp
Object code VAR
Data type UNSIGNED32
Category Optional
Entry description:
Access Read/Write
PDO mapping No
Value range 0…0xFFFFFFFF
Default value 0
CANopen DS 301 Implementation Guide Device-specific Objects
MAN-CAN301IG (Ver. 2.1)
12-10
Zobrazit stránku 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 117 118

Komentáře k této Příručce

Žádné komentáře