Elmomc SimplIQ Digital Servo Drives-Bell Command Referenc Uživatelský manuál Strana 21

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 315
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 20
Limit Ranges
The following table lists the value ranges for defining the limits of the system.
Subject Values
Position counter ranges Main position counter is subjected to a modulo
counting with the following ranges:
XM[1]: Lowest value
XM[2]: Highest value
Range: [-5x10
8
…5x10
8
] counts
Auxiliary position counter is limited to:
YM[1]: Lowest value
YM[2]: Highest value
Range: [-5x10
8
…5x10
8
] counts
Velocity range Range for Quadrature Encoder:
[-40,000,000…40,000,000] counts/sec
Range for other feedbacks:
[-80,000,000…80,000,000] counts/sec
EF[1]: Filter for main velocity sensor
EF[2]: Filter for auxiliary velocity sensor
Acceleration/Deceleration ranges Range: [100…1,000,000,000]
Stop deceleration range Range: [100…1,000,000,000]
Torque limits Range of torque command is subjected to the
following limits:
CL[1], PL[1]
Range: [-MC…MC]
Note:
The multiplication of the PWM frequency
reduces the torque limit.
Table 3-1: Limit Ranges
SimplIQ for Steppers Command Reference Manual Alphabetical Listing
MAN-STECR (Ver. 1.1)
13
Zobrazit stránku 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 314 315

Komentáře k této Příručce

Žádné komentáře