0x8 0x4 0x2 Meaning
0 0 0 OK.
0 0 1 Under-voltage: The power supply is shut off or it has too high
an impedance.
0 1 0 Over-voltage: The power supply voltage is too large, or the
servo drive did not succeed in absorbing the kinetic energy
while braking a load. A shunt resistor may be needed.
1 0 1 Short circuit: The motor or its wiring may be defective.
1 1 0 Temperature: The drive is overheating.
Table 3-43: Servo Drive Status Indications
Attributes: Type: Status report, Integer, Bit-field
Source: Program, RS-232, CANopen
Restrictions: None
Unit modes: All
SimplIQ: Similar
See also:
MF
, RR, PM, UM, RM, IP, MS, MO, LC, HM[N], HY[N]